[Product
Overview ] [Part Number Breakdown]
Determining
Impedance Vs. Insertion Loss
Electrical Performance
Standard
filter characteristics are shown. Custom requirements
are available in many arrangements. filter types may be
mixed within a connector as well as grounded and/or unfiltered
pins may be added. Please contact the factory for your
specifications and delivery requirements.
Pi Filter
| CAPACITANCE
INDICATOR |
5 |
4 |
3 |
2 |
1 |
| STD.
OPERATING TEMP. RANGE |
-55°C
to +125°C |
| WORKING
VOLTAGE |
100 VDC |
200
VDC |
| CURRENT
RATING RF |
3.0
amps min. (higher available upon request |
| INSULATION
RESISTANCE/ D.W.V. |
5000 megohms
min at 100 VDC |
5000
megohms min at 100 VDC |
| CAPACITANCE
IN PICOFARADS AT 1 kHz, .1 VRMS |
32,000
45,000 |
8000
12,000 |
3300
5000 |
850
1300 |
400
600 |
ATTENUATION
MINIMUMS
per MIL-STD-220 at 25°C
without bias Voltage or current |
Freq.
MHz |
8 |
2 |
- |
- |
- |
| 1 |
| 5 |
20 |
10 |
3 |
- |
- |
| 10 |
40 |
18 |
9 |
5 |
3 |
| 100 |
60 |
60 |
45 |
32 |
23 |
| 500
to 1000 |
62 |
62 |
55 |
50 |
38 |

C Filter
| CAPACITANCE
INDICATOR |
5 |
4 |
3 |
2 |
1 |
| STD.
OPERATING TEMP. RANGE |
-55°C
to +125°C |
| WORKING
VOLTAGE |
100 VDC |
200
VDC |
| CURRENT
RATING RF |
3.0
amps min. (higher available upon request |
| INSULATION
RESISTANCE/ D.W.V. |
5000 megohms
min at 100 VDC |
5000
megohms min at 100 VDC |
| CAPACITANCE
IN PICOFARADS AT 1 kHz, .1 VRMS |
16,000
22,500 |
4000
6000 |
1650
2500 |
425
650 |
200
300 |
ATTENUATION
MINIMUMS
per MIL-STD-220 at 25°C
without bias Voltage or current |
Freq.
MHz |
5 |
- |
- |
- |
- |
| 1 |
| 5 |
15 |
2 |
- |
- |
- |
| 10 |
26 |
8 |
5 |
3 |
- |
| 100 |
42 |
30 |
25 |
20 |
15 |
| 500
to 1000 |
50 |
43 |
40 |
33 |
30 |