TEST DESCRIPTION PARAMETERS
Durability 500 cycles of mating and unmating
Temperature Range Class F, C,  K, Y & N:   -65°C (-85°F) to +200°C (392°F)
Class W: -65°C (-85°F) to + 175°C (347°F)
Vibration Mated connectors with weights attached to simulate rear accessory loads, withstand the following vibration levels:

Sine vibration per MIL-STD 202, Method 204, Condition G

Random vibration per M I L-STD-1344, Method 2005, Condition VI,  Letter "J"

   
Shielding Effectiveness Class F & N: EMI leakage attenuation, greater than 9OdB at I00Mhz, and greater than 65dB at 10Ghz. Shell-to-Shell conductivity, 1.0 millivolt maximum voltage drop.
Class W: EMI leakage attenuation, greater than 90dB at I00Mhz,   and greater than 50dB at 10GHz.  Shell-to-Shell conductivity, 2.5 millivolt maximum voltage drop.
Class K & Y: EMI leakage attenuation, greater than 80dB at 100Mhz, and greater than 45dB at I0Ghz.  Shell-to-Shell  conductivity, I0.0 millivolt maximum voltage drop.
 
Corrosion Resistance Class C, W, K & Y withstand 500 hours Salt Spray
Class F & N withstand 48 hours Salt Spray
Fluid Immersion Connectors withstand specified immersions in various fuels, solvents, coolants and oils, per MIL-STD-1344, Method 1016
Pin-to-Pin Mating Protection A plug and receptacle will not mate with connectors having the same contact gender.
Scoop-Proof Design Pin contacts are recessed to prevent damage due to scooping by the mating connector shell.
Grounding Before Contact Complete grounding between connector halves occurs  0.050 inch (1.27mm) before engagement of the electrical contacts.

wpe34599.gif (39449 bytes)

wpe58676.gif (43859 bytes)

wpe62358.gif (23565 bytes)

wpe64921.gif (28605 bytes)

wpe05369.gif (32097 bytes)

 

To Recieve a quote on this product, please contact March Electronics. To get local office information Click Here

 

 
 
 
 

Terms and Conditions | Supplier QA Requirements | AS9100 Certificate
Product Request Form | Request for Quotation | Sales Representatives
Mission-Management| Driving Directions | Customer Feedback


Copyright © 1999 G&H Technology, Inc. All rights reserved.
G&H Technology, Inc., 750 West Ventura Blvd Camarillo, CA  93010
Toll-Free: (800) 840-0502 Phone: (805) 484-0543 Fax: (805) 987-5062 E-mail:
ghtech@ghtech.com

Last Modified: